What is COP?
COP = heat output ÷ electrical input. An electric element has a COP of 1. Pecol heat pumps have rated COPs from 3.4 (compact wall-mounted) to 5.4 (R290 eco all-in-one), and up to about 5 for commercial Class I applications.
EER (energy efficiency ratio) is the same idea for cooling: cooling output ÷ electrical input. Pecol reversible air to water heat pumps have an EER of about 3.0.
What affects COP
- Air temperature: warmer air gives a higher COP. Malaysia's 24–35°C climate is ideal.
- Water temperature: the hotter the water you want, the lower the COP. 50–55°C is a good setting for homes.
- Refrigerant: R290 and R32 are very efficient; R134A reaches higher water temperatures.
- Compressor and controls: DC inverter and EVI compressors keep COP high at part load.
- Heat exchanger condition: dust on the coil or scale in the water side lowers COP.
| Temperature class | Temperature rise | COP |
|---|---|---|
| I | 18°C | 5.0–8.0 |
| II | 33°C | 3.3–5.0 |
| III | 43°C | 3.0–3.5 |
COP at Malaysian ambient temperatures
| Pecol model | Test condition | COP |
|---|---|---|
| R290 eco all-in-one | Rated | 5.4 |
| DC inverter split DCSAHP | Rated | 4.58 |
| All-in-one 160 / 200 L | Rated | 4.25 |
| R32 DC inverter air to water | Air 20°C, water 15→55°C | 4.73–4.95 |
| DHW monoblock WHP-HW | Air 20°C, water 15→55°C | 4.2–4.3 |
| Pool heat pump R32 inverter | Air 26°C, pool 26→28°C | up to 13.3 |
Because typical Malaysian air is warmer than most test conditions, real-world hot water COP is often at or above the rated value.
Keep your heat pump at optimal performance
- Keep 0.5–1 m clear space around the air inlet and outlet.
- Clean the evaporator coil and filters regularly.
- Use ECO (heat pump only) mode and a 50–55°C setting for daily use.
- Insulate hot water pipes and fix leaks.
- Have the unit serviced yearly: refrigerant, water flow and electrical checks. See maintenance.
How heat pumps reduce energy consumption
28°C to 55°C, 30 days.