Air to Water Heat Pump for Cooling and Heating

Reversible air to water heat pumps can make chilled water for cooling, hot water for showers, and warm water for floor heating or radiators, all from one outdoor unit. In Malaysia the most useful combination is hot water plus cooling; in cooler highlands and export markets, space heating is added.

Pecol reversible air to water heat pump

Five operating modes

ModeWhat it doesTypical use
1. Domestic hot waterConstant-temperature hot water, 24 hoursHomes, hotels, hostels
2. Space coolingChilled water to fan coil units (water-cooled air-conditioning)Bungalows, offices, showrooms
3. Space heatingWarm water to floor heating, fan coils or radiatorsHighland homes and resorts
4. Hot water + coolingCooling and hot water at the same timeTropical homes and hotels
5. Hot water + heatingHot water and space heating togetherCold climates

Cooling with an air to water heat pump

In cooling mode the cycle reverses: the heat pump removes heat from water and rejects it outdoors, producing chilled water at 5–20°C. The chilled water circulates to fan coil units in each room, a quiet form of air-conditioning with no refrigerant pipes inside the house. Pecol's R32 DC inverter models give 8.3–22.1 kW of cooling at an EER of about 3.0.

ModelWHP030-R3DCWHP045-R3DCWHP060-R3DCWHP080.3N-R3DC
Cooling capacity (A35, W12/7)8.3 kW12.2 kW15.5 kW22.1 kW
Rated input2.76 kW4.1 kW5.03 kW7.16 kW
EER3.012.983.083.09

Underfloor heating, fan coils and radiators

Low water temperatures make heat pumps most efficient, so underfloor heating (30–35°C water) is the best match; the R32 DC inverter models reach COP 4.25–4.62 at these conditions. Radiators need hotter water (45–55°C) and run at a lower COP (about 3). Cold-climate EVI models keep heating down to -30°C. A buffer tank is recommended for multi-zone heating or cooling.

Most Malaysian lowland homes do not need space heating. If you are comparing a gas boiler replacement or underfloor heating for a highland property or an overseas project, Pecol can design the system.

Air to air vs air to water

An air to air heat pump (a reversible air-con) cannot heat water. If you want both cooling and hot water, choose a reversible air to water heat pump, or add heat reclaim to an air-con. See heat pumps and air-conditioning.

Frequently asked questions

Can an air source heat pump cool?
Yes, reversible models make chilled water for fan coils. Standard hot-water-only models do not cool, but they blow out cool air as a by-product.
Can an air to water heat pump replace a boiler?
Yes, for hot water and heating. It is cheaper to run and has no flame or flue.
Is underfloor heating with a heat pump efficient?
Very. Underfloor heating uses low water temperatures, where heat pumps reach their best COP.