Five operating modes
| Mode | What it does | Typical use |
|---|---|---|
| 1. Domestic hot water | Constant-temperature hot water, 24 hours | Homes, hotels, hostels |
| 2. Space cooling | Chilled water to fan coil units (water-cooled air-conditioning) | Bungalows, offices, showrooms |
| 3. Space heating | Warm water to floor heating, fan coils or radiators | Highland homes and resorts |
| 4. Hot water + cooling | Cooling and hot water at the same time | Tropical homes and hotels |
| 5. Hot water + heating | Hot water and space heating together | Cold climates |
Cooling with an air to water heat pump
In cooling mode the cycle reverses: the heat pump removes heat from water and rejects it outdoors, producing chilled water at 5–20°C. The chilled water circulates to fan coil units in each room, a quiet form of air-conditioning with no refrigerant pipes inside the house. Pecol's R32 DC inverter models give 8.3–22.1 kW of cooling at an EER of about 3.0.
| Model | WHP030-R3DC | WHP045-R3DC | WHP060-R3DC | WHP080.3N-R3DC |
|---|---|---|---|---|
| Cooling capacity (A35, W12/7) | 8.3 kW | 12.2 kW | 15.5 kW | 22.1 kW |
| Rated input | 2.76 kW | 4.1 kW | 5.03 kW | 7.16 kW |
| EER | 3.01 | 2.98 | 3.08 | 3.09 |
Underfloor heating, fan coils and radiators
Low water temperatures make heat pumps most efficient, so underfloor heating (30–35°C water) is the best match; the R32 DC inverter models reach COP 4.25–4.62 at these conditions. Radiators need hotter water (45–55°C) and run at a lower COP (about 3). Cold-climate EVI models keep heating down to -30°C. A buffer tank is recommended for multi-zone heating or cooling.
Air to air vs air to water
An air to air heat pump (a reversible air-con) cannot heat water. If you want both cooling and hot water, choose a reversible air to water heat pump, or add heat reclaim to an air-con. See heat pumps and air-conditioning.